Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Clinics (Sao Paulo) ; 64(3): 215-21, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19330248

RESUMO

PURPOSE: Cardiopulmonary bypass is known to alter propofol pharmacokinetics in patients undergoing cardiac surgery. However, few studies have evaluated the impact of these alterations on postoperative pharmacodynamics. This study was designed to test the hypothesis that changes in propofol pharmacokinetics increase hypnotic effects after cardiopulmonary bypass. METHODS: Twenty patients scheduled for on-pump coronary artery bypass graft (group, n=10) or off-pump coronary artery bypass graft (group, n=10) coronary artery bypass grafts were anesthetized with sufentanil and a propofol target controlled infusion (2.0 microg/mL). Depth of hypnosis was monitored using the bispectral index. Blood samples were collected from the induction of anesthesia up to 12 hours after the end of propofol infusion, at predetermined intervals. Plasma propofol concentrations were measured using high-performance liquid chromatography, followed by a non-compartmental propofol pharmacokinetic analysis. Data were analyzed using ANOVA, considering p<0.05 as significant. RESULTS: After cardiopulmonary bypass, despite similar plasma propofol concentrations in both groups, bispectral index values were lower in the on-pump coronary artery bypass graft group. Time to extubation after the end of propofol infusion was greater in the on-pump coronary artery bypass graft group (334 +/- 117 vs. 216 +/- 85 min, p = 0.04). Patients undergoing cardiopulmonary bypass had shorter biological (1.82 +/- 0.5 vs. 3.67 +/- 1.15 h, p < 0.01) and terminal elimination (6.27 +/- 1.29 vs. 10.5h +/- 2.18, p < 0.01) half-life values, as well as higher total plasma clearance (28.36 +/- 11.40 vs.18.29 +/- 7.67 mL/kg/min, p = 0.03), compared to patients in the off-pump coronary artery bypass graft group. CONCLUSION: Aside from the increased sensitivity of the brain to anesthetics after cardiopulmonary bypass, changes in propofol pharmacokinetics may contribute to its central nervous system effects.


Assuntos
Anestésicos Intravenosos/farmacocinética , Monitores de Consciência , Ponte de Artéria Coronária sem Circulação Extracorpórea , Doença da Artéria Coronariana/cirurgia , Propofol/farmacocinética , Idoso , Anestésicos Intravenosos/sangue , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Masculino , Pessoa de Meia-Idade , Propofol/sangue
2.
Clinics ; 64(3): 215-221, 2009. graf, tab
Artigo em Inglês | LILACS | ID: lil-509435

RESUMO

PURPOSE: Cardiopulmonary bypass is known to alter propofol pharmacokinetics in patients undergoing cardiac surgery. However, few studies have evaluated the impact of these alterations on postoperative pharmacodynamics. This study was designed to test the hypothesis that changes in propofol pharmacokinetics increase hypnotic effects after cardiopulmonary bypass. METHODS: Twenty patients scheduled for on-pump coronary artery bypass graft (group, n=10) or off-pump coronary artery bypass graft (group, n=10) coronary artery bypass grafts were anesthetized with sufentanil and a propofol target controlled infusion (2.0 µg/mL). Depth of hypnosis was monitored using the bispectral index. Blood samples were collected from the induction of anesthesia up to 12 hours after the end of propofol infusion, at predetermined intervals. Plasma propofol concentrations were measured using high-performance liquid chromatography, followed by a non-compartmental propofol pharmacokinetic analysis. Data were analyzed using ANOVA, considering p<0.05 as significant. RESULTS: After cardiopulmonary bypass, despite similar plasma propofol concentrations in both groups, bispectral index values were lower in the on-pump coronary artery bypass graft group. Time to extubation after the end of propofol infusion was greater in the on-pump coronary artery bypass graft group (334 ± 117 vs. 216 ± 85 min, p = 0.04). Patients undergoing cardiopulmonary bypass had shorter biological (1.82 ± 0.5 vs. 3.67 ± 1.15h, p < 0.01) and terminal elimination (6.27 ± 1.29 vs. 10.5h ± 2.18, p < 0.01) half-life values, as well as higher total plasma clearance (28.36 ± 11.40 vs.18.29 ± 7.67 mL/kg/min, p = 0.03), compared to patients in the off-pump coronary artery bypass graft group. CONCLUSION: Aside from the increased sensitivity of the brain to anesthetics after cardiopulmonary bypass, changes in propofol pharmacokinetics may contribute to its central nervous system effects.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anestésicos Intravenosos/farmacocinética , Monitores de Consciência , Ponte de Artéria Coronária sem Circulação Extracorpórea , Doença da Artéria Coronariana/cirurgia , Propofol/farmacocinética , Anestésicos Intravenosos/sangue , Cromatografia Gasosa-Espectrometria de Massas , Propofol/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...